Core Fire Department Specification

The NERIS incident fire module specification details the fire specific information.

 
 

Data Framework

The data framework provides fields and definitions for the data.

General

 
 

For all cases

  • incident_subcategory - The subcategory that defines the type of fire found upon arrival
  • involve_emerging_hazard - If incident involves electrification, PV systems, or CSST
  • civilian_rescues - The number of civilians rescues during the incident
  • civilian_evac - The number of civilians evacuated or assisted out of non-IDLH areas during the incident.
  • ff_rescues - The number of firefighters rescued from IDLH environments during the incident.
  • pet_rescues - The number of pets rescued from IDLH environments during the incident.  
     

If in a structure

  • fire_arrival_conditions - The fire conditions upon arriving on the scene of the incident
  • fire_progression_conditions - Did the fire extend beyond the conditions found upon arrival?
  • fire_bldg_damage - Rating of damage to the fire building of origin as selected from a list of values
  • fire_exposure - If exposure to other properties or units within property
  • property_floor_of_origin - The story above or below ground of fire origin
  • water_supply - Describes the type of water supply utilized for the incident.
  • total_occupants - Describes the total number of occupants in the fire building
  • displaced_occupants - Describes the total number of occupants displaced
  • displaced_number - Describes the total number of occupants displaced
  • displaced_cause - Cause for displacement
  • inv_need - Assessment by incident commander and/or officer in charge of the incident as to whether the fire necessitated a formal fire investigation.
  • inv_fire_in - Categorizes the general type of investigation completed at the structure fire incident. Complete only if a formal cause and origina investigation was completed at the incident.
  • fire_cause_in - General categorization of the cause (or likely cause) of the structure fire.  
     

In Structure: Fire protection

  • detector_presence - Describes whether a detector was present in the area of the fire
  • detector_type - If a detector was present, describes the type of detector located
  • detector_power_supply - If a detector was present, describes the power supply of the detector
  • detector_operation - If a detector was present, describes whether the detector operated during incident
  • detector_failure_to_operate - If the detector failed to operate, describes the reason for the failure
  • detector_effectiveness - If the detector operated, describes the result of the operation
  • aes_presence - Describes the presence of an Automatic Extinguishing System
  • aes_type - If the fire was within range of the Automatic Extinguishing System, describes the type of AES
  • aes_operation - If the fire was within range of the Automatic Extinguishing System, describes the operation of the AES
  • sprinkler_heads_operating - If the AES operated, the number of sprinkler heads activated
  • aes_failure_reason - If the AES failed or was ineffective, the reason for the failure  
     

If outside

  • fire_exposure - Identifies if exterior fire transitions to exposure
  • inv_need - Assessment by incident commander and/or officer in charge of the incident as to whether the fire necessitated a formal fire investigation.
  • inv_fire_out - Categorizes the general type of investigation completed at the structure fire incident. Complete only if a formal cause and origina investigation was completed at the incident.
  • fire_cause_out - General categorization of the cause (or likely cause) of the outside fire.
  • fire_acres_burned - Estimated number of acres burned during the incident
  • IRWIN_connect - Pull additional information from IRWIN for wildfires  
     

Data Framework Details

General

Attribute Definition Comment Mandatory
 
 

For all cases

Attribute Definition Comment Mandatory
incident_subcategory The subcategory that defines the type of fire found upon arrival See final_incident_type Yes
involve_emerging_hazard If incident involves electrification, PV systems, or CSST If yes, prompts emerging_hazard_submodule Yes
civilian_rescues The number of civilians rescues during the incident Rescue is removal of viable/potentially viable occupant from IDLH to point of additional care where firefighters are under direct threat to bodily harm, including death. Yes
civilian_evac The number of civilians evacuated or assisted out of non-IDLH areas during the incident. Evacuation is the removal of occupants from non-IDLH areas, including non-attached and attached adjacent exposures by firefighters. Yes
ff_rescues The number of firefighters rescued from IDLH environments during the incident. Rescue of a firefighter is the removal of a member from IDLH to the point additional care can be provided. If this is one or greater than it must also be reflected in core_module line 10 Yes
pet_rescues The number of pets rescued from IDLH environments during the incident. Rescue of a pet involves the removal of a viable/potentially viable animal designed for human companionship from inside a structure in an IDLH. Yes
 
 

If in a structure

Attribute Definition Comment Mandatory
fire_arrival_conditions The fire conditions upon arriving on the scene of the incident Yes
fire_progression_conditions Did the fire extend beyond the conditions found upon arrival? Yes
fire_bldg_damage Rating of damage to the fire building of origin as selected from a list of values Minor (smoke, water, scorch, radiant heat absorbtion, limited fire), Moderate (damage but still functional, includes flame, water, smoke damage), Major (flame or water damage resulting in total loss of the exposed property) Yes
fire_exposure If exposure to other properties or units within property If Yes, prompts exposure_submodule Yes
property_floor_of_origin The story above or below ground of fire origin Negative integer is below ground, positive is above ground. 1 is ground floor. Yes
water_supply Describes the type of water supply utilized for the incident. Yes
total_occupants Describes the total number of occupants in the fire building This will include both residential and non-residential structures Yes
displaced_occupants Describes the total number of occupants displaced This will include both residential and non-residential structures Yes
displaced_number Describes the total number of occupants displaced This will include both residential and non-residential structures Yes
displaced_cause Cause for displacement This will include both residential and non-residential structures Yes
inv_need Assessment by incident commander and/or officer in charge of the incident as to whether the fire necessitated a formal fire investigation. Yes
inv_fire_in Categorizes the general type of investigation completed at the structure fire incident. Complete only if a formal cause and origina investigation was completed at the incident. Prompts investigation module; multiple selections allowed. Yes
fire_cause_in General categorization of the cause (or likely cause) of the structure fire. Yes
 
 

In Structure: Fire protection

Attribute Definition Comment Mandatory
detector_presence Describes whether a detector was present in the area of the fire If yes, select from followup list. Yes
detector_type If a detector was present, describes the type of detector located If yes, select from followup list. Yes
detector_power_supply If a detector was present, describes the power supply of the detector If yes, select from followup list. Yes
detector_operation If a detector was present, describes whether the detector operated during incident Yes
detector_failure_to_operate If the detector failed to operate, describes the reason for the failure Yes
detector_effectiveness If the detector operated, describes the result of the operation Yes
aes_presence Describes the presence of an Automatic Extinguishing System Yes
aes_type If the fire was within range of the Automatic Extinguishing System, describes the type of AES Yes
aes_operation If the fire was within range of the Automatic Extinguishing System, describes the operation of the AES Yes
sprinkler_heads_operating If the AES operated, the number of sprinkler heads activated Yes
aes_failure_reason If the AES failed or was ineffective, the reason for the failure Yes
 
 

If outside

Attribute Definition Comment Mandatory
fire_exposure Identifies if exterior fire transitions to exposure If yes, prompts exposure_submodule Yes
inv_need Assessment by incident commander and/or officer in charge of the incident as to whether the fire necessitated a formal fire investigation. Yes
inv_fire_out Categorizes the general type of investigation completed at the structure fire incident. Complete only if a formal cause and origina investigation was completed at the incident. Allow for multiple selections then require incident analysis/investigation model to be completed for formal information about the fire. Yes
fire_cause_out General categorization of the cause (or likely cause) of the outside fire. No
fire_acres_burned Estimated number of acres burned during the incident Yes
IRWIN_connect Pull additional information from IRWIN for wildfires Computed
 
 

Data Framework Examples

General

Attribute Example
 
 

For all cases

Attribute Example
incident_subcategory Structure, Outside, Vehicle
involve_emerging_hazard Yes OR No
civilian_rescues 0, 1, etc.
civilian_evac 0, 1, etc.
ff_rescues 0, 1, etc.
pet_rescues 0, 1, etc.
 
 

If in a structure

Attribute Example
fire_arrival_conditions no smoke/fire showing, smoke showing, smoke and fire showing, structure involved, fire spread beyond stucture
fire_progression_conditions Yes OR No
fire_bldg_damage Severe
fire_exposure Yes OR No
property_floor_of_origin 1
water_supply hydrant (est. flow < 500 GPM), hydrant (est flow > 500 GPM), tank water, water tender (shuttle), nursing from other apparatus, other, n/a
total_occupants 5
displaced_occupants Yes OR No
displaced_number 2
displaced_cause Smoke, Fire, Water (check all that apply)
inv_need Yes, No, Not Evaluated, Not Applicable, No - Cause Obvious, Other
inv_fire_in Investigated by on scene operational resources, Investigated by formal arson/fire investigator, investigated by outside fire agency, investigated by state fire marshal, investigated by insurance, investigated by law enforcement (non-fire), investigated by other
fire_cause_in Operating equipment, electrical, heat from another object, explosives/fireworks, smoking materials or illicit drugs, open flame, chemical, act of nature, incendiary, other heat source
 
 

In Structure: Fire protection

Attribute Example
detector_presence None Present, Present, Undetermined
detector_type Smoke, Heat, Sprinkler, Carbon Monoxide, Natural Gas, Other Chemical Detector
detector_power_supply Battery, Hardwire, Plug-in
detector_operation Operated, Nothing to Detect, Failed to Operate
detector_failure_to_operate Power Failure, Improper Installation, Malfunction, Tamper
detector_effectiveness Alerted Occupants, Failed to Alert Occupants
aes_presence None, Present, Partual System, Undetermined
aes_type Wet-pipe sprinkler, dry-pipe sprinkler, etc.
aes_operation Operated/Effective, Operated/Not Effective, Failed to Operate, etc.
sprinkler_heads_operating 3
aes_failure_reason System Shut-Off, System Damaged, etc.
 
 

If outside

Attribute Example
fire_exposure Yes OR No
inv_need Yes, No, Not Evaluated, Not Applicable, No - Cause Obvious, Other
inv_fire_out Investigated by on scene operational resources, Investigated by formal arson/fire investigator, investigated by outside fire agency, investigated by state fire marshal, investigated by insurance, investigated by law enforcement (non-fire), investigated by other
fire_cause_out Spread from controlled burn, operating equipment, electrical, heat from another object, explosives/fireworks, smoking materials or illicit drugs, open flame, chemical, act of nature, incendiary, other heat source
fire_acres_burned 0.5
IRWIN_connect
 
 

 
 