NERIS FAQ | NERIS Specification | NERIS Fire Department Specification | NERIS Incident Specification
Note: NERIS is currently a draft specification (where this is based upon version: V0.1 - December 2023) and is subject to change.
The NERIS incident EMS module specification details the emergency medical service information.
The data framework provides fields and definitions for the data.
Attribute | Definition | Comment | Mandatory |
---|---|---|---|
number_of_patients | The total number of patients treated | NEMSIS NumberOfPatientsAtScene | Yes |
patient_number | The specific patient number out of those treated | Yes | |
provider_impression | The provider’s assessment of the medical emergency | See provider_impression sheet | Yes |
procedures_used | If treatment was given, the types of procedures attempted | EMS actions taken sheet is in development | Yes |
patient_evaulation_care | Status of patient care needs based on evaluation | NEMSIS list PatientEvaluationCare with five options | Yes |
patient _improved_status | Status of the patient after FD arrival and intervention | NEMSIS values for Response –Improved (9916001) Unchanged (9916003), 9916005 (Worse) | Yes |
ems_disposition | The transport outcome of the incident | Yes | |
hospital_destination | If transported by the FD, the Care Faility destination | If not recorded in CAD / NEMSIS value HospitalDestination | Yes |
ems_property | If response in a structure | If yes – OPTIONAL – complete ems fire protection questions | Yes |
Attribute | Definition | Comment | Mandatory |
---|---|---|---|
property_floor_of_origin | The story above or below ground of fire origin | Negative integer is below ground, positive is above ground. 1 is ground floor. | No |
detector_presence | Describes whether a detector was present in the area of the fire | If yes, select from followup list. | No |
detector_type | If a detector was present, describes the type of detector located | If yes, select from followup list. | No |
detector_power_supply | If a detector was present, describes the power supply of the detector | If yes, select from followup list. | No |
Attribute | Example |
---|---|
number_of_patients | 2 |
patient_number | 1 |
provider_impression | Abdominal Pain |
procedures_used | Bleeding Control, Burn Care, etc. |
patient_evaulation_care | patient evaluated and care provided (4228001) |
patient _improved_status | Improved (9916001) |
ems_disposition | FD Transport to Care Facility, Non-FD Transport, No Transport, etc. |
hospital_destination | Washington Adventist Hospital, White Oak Medical Center, Etc. |
ems_property | Yes OR No |
Attribute | Example |
---|---|
property_floor_of_origin | 1 |
detector_presence | None Present, Present, Undetermined |
detector_type | Smoke, Heat, Sprinkler, Carbon Monoxide, Natural Gas, Other Chemical Detector |
detector_power_supply | Battery, Hardwire, Plug-in |
Need more help with NFIRS, or not yet found what you are looking for? Please see if these help …
For more information see the NFIRS Cheat Sheet, NFIRS Coding and contact Responserack to learn about our fire department software.